Overload / Overrange
- What is the difference ?
Two easily
overlooked, yet extremely critical parameters when evaluating
and specifying torque transducers are Mechanical Overload
Rating and Electrical Overrange. Each is important, but often
confused and misunderstood.
Overload represents a mechanical safety factor for the
sensor element.
Normally expressed as a percentage of the sensor full scale rating,
it is the maximum load limit of the sensor before yield or physical
deformation. S Himmelstein and Company products are available
in a variety of overload ratings typically either 200%,
400% or even 1,000%.
The sensors are designed for infinite fatigue life for operation
at or below one-half of its mechanical overload rating.
The overload region from one-half the overload rating
up to the full overload rating should be reserved as safety
factor for occasional unexpected events. Operation in the overload
region will not immediately damage the unit, but repeated operation
or frequent cycles into the overload region will decay the fatigue
life to a finite value and may eventually lead to a fatigue failure.
Operation above the full overload rating may result in physical
deformation or yielding of the sensor element or strain gages.
This loading will not cause a catastrophic failure but will be
evidenced by a significant permanent zero offset.
By way of example, a 1,000 lbf-in (113 Nm) sensor with a 400%
overload rating, will have a
maximum overload of 4,000 lbf-in (452 Nm). The infinite fatigue
life loading limit would be onehalf its overload rating,
or 2,000 lbf-in (226 Nm). Operation between 2,000 lbf-in (226
Nm) and
4,000 lbf-in (452 Nm) will not damage the unit but will start
to decay the fatigue life. Loading
above 4,000 lbf-in may result in a permanent zero offset.

Overrange
is a parameter that relates to the sensors electrical output
signal. Also expressed as a percentage of the sensor full scale
rating, it represents how far the output voltage will extend
beyond full scale. The majority of S. Himmelstein and Company
sensors now incorporate
integrated signal conditioning electronics for processing of
the sensor strain gage signal.
The analog outputs are normally configured such that 10 Vdc will
be equal to the sensor full scale rating. Unlike most manufacturers,
the outputs of Himmelstein sensors are not clipped at full scale
or 10 Vdc, they will typically have an overrange of 150% allowing
the output signal to extend to 15 Vdc. This feature will avoid
clipping of oscillatory signal components occurring at or near
full scale that are inevitable in rotating applications. The
result will be a more accurate representation of the average
value.
S. Himmelstein and Company has published a technical document
with a more detailed discussion Application Note 20805B.

For
more information, please contact :
S. Himmelstein and Company
2490 Pembroke Avenue, Hoffman Estates, IL 60169 USA
Tel: 847-843-3300
Fax: 847-843-8488
Wedbsite: www.himmelstein.co